ASSESSMENT OF THE ACCURACY OF SURGICAL GUIDE DESIGNED FROM CBCT WITH DIFFERENT VOXEL SIZES IN COMPUTER GUIDED IMPLANTOLOGY: RANDOMIZED CLINICAL TRIAL

Mohammed Mohammed Ahmed Elhag, Ahmed M. Abd Alsamad And Mushira M. Dahaba,

ABSTRACT

Objectives: The Present Study Was Designed To Assess The Effect Of CBCT With Different Voxel Sizes On The Accuracy Of Surgical Guide Fabrication On Computer Guided Implantology.

Materials and Methods: This Study Was Conducted On Ten Patients. The Patients Were Divided Into Two Groups. One Group Received Dental Implants Using Surgical Guides Designed From CBCT With 0.2 Mm Voxel Size While The Other Group Received Dental Implants Using Surgical Guides Designed From CBCT With 0.4 Mm Voxel Size. The Patients Were Asked For Post-operative CBCT To Compare The Accuracy The Surgical Guide. Linear And Angular Deviations Were Measured Between Planned And Actual Position In Both Groups. The Results Were Tabulated And Statistically Analyze.

Results: Surgical Guides Manufactured With CBCT Of 0.2 Mm Voxel Size Showed Statistically Significantly Lower Median Linear And Angular Deviation Than Surgical Guides Manufactured With CBCT Of 0.4 Mm Voxel In BL Direction. While There Was No Statistically Significantly Difference Between The Two Groups In Linear And Angular Deviation In MD Direction. Conclusion : There Was No Clinical Significantly Clinical Difference In Linear And Angular Accuracy Between Surgical Guides Manufactured From CBCT With Voxel Size Either 0.2mm Or 0.4 Mm.

ADVANCED SEARCH

© Copyright 2019, All Rights Reserved. | Powered by HPH