ABSTRACT
Measurements Of Inter Implant Distance Through Two Various Methods Were Evaluated And Compared.
Materials and Methods: Fifteen Completely Edentulous Patientswith Two Mandibulary Inserted Implant Were Selected For This Study. The Distance Between Two Implants Was Measured In The Computerized Way Using Cone Beam Software. The Inter- Implant Distance Was Measured By Clinical Way Using Digital Caliper. The Data Gained By 2 Ways Of Measurements Were Compared.
Results: The Calculated Mean Of Clinically Measured Inter-implant Distances Was
(25.149� 4.9244) While Cone Beam Measurements Of Inter Implant Distancewas (25.375� 4.7777) Of The Same Distance Revealing No Significant Difference Between Both Method.
Conclusion: No Significant Differences Between Inter Implants Distances By Using Clinical Measurements Distances And Post-operative Distances On The Cone Beam.