TRANSLUCENCY OF MONOLITHIC VERSUS LAYERED ZIRCONIA IN THREE DIFFERENT SHADES

Muhammad Adel Ali Erfan, Amany Mohammed Korsel And Gaber Ibrahim Masoud,

ABSTRACT


Purpose: This Study Aimed To Compare The Translucency Of Monolithic Versus Layered Zirconia In Three Different Shades, A1, A2, And A3.

Materials & Methods: 30 Disc Specimens Of 10 Mm Diameter And 2 Mm Thickness Were Divided In 2 Main Groups. Group I (Monolithic), And Group II (Layered), With A Count Of 15 Specimens Foeach Group. Group I Specimens Were Fabricated Entirely From CAD/CAM Ceramill?Zolid Zirconia, While Group II Had Cores Of 1mm Thickness Ceramill?Zolid Zirconia Veneered With 1mm Thickness VITA VM?9 Porcelain. Each Group Was Divided Into 3 Subgroups According To The Different Shades Used (A1, A2, And A3). All Specimens Were Tested Using UV Spectrophotometer, (Cary 5000, Agilent Technologies, USA). Translucency Parameter (TP) And Contrast Ratio (CR) Of All Specimens Were Calculated. Data Were Statistically Analyzed With F-test (ANOVA) And Student T-test.

Results: The Statistical Analysis Showed Significant Results In Comparing The Different Techniques Of Fabrications. On Comparing The Mean Values Of All Study Subgroups, Subgroup II-A1 Showed The Highest TP (TP = 5.91) And The Lowest CR (CR = 0.85), Followed By Subgp. II-A2 (TP = 5.697 / CR = 0.853), Subgp.II-A3 (TP = 5.45 / CR = 0.87), Subgp.I-A1 (TP = 4.24 / CR = 0.893), Subgp. I-A2 (TP = 4.128 / CR = 0.903), And I-A3 As The Lowest TP (TP = 4.014) And The Highest CR (CR = 0.927). On The Contrary, Insignificant Results Were Observed When Comparing Different Shades Within The Same Main Group (p � 0.05). Conclusion: The Fabrication Techniques Affected Specimen Translucency Significantly, Where Group II Showed A Significant Higher TP Than Group I. On The Other Hand, Different Color Shades Used In The Present Study Showed Insignificant Effect On The Specimens TP Values In The Same Group.

Read More »

IMMEDIATE IMPLANT PLACEMENT WITH DEPROTEINIZED BOVINE BONE (TUTOGEN) VERSUS PLACEMENT OF PRF AS A SPACE FILLING MATERIAL IN MANDIBULAR MOLARS. RANDOMIZED CLINICALTRIAL

Ahmed El Garhy, Mohammed Atef And Niveen Askar,

ABSTRACT
Objective: The Present Study Conducted To Compare The Regenerative Potential Of Guided Bone Regeneration (control Group) To Platelet Rich Fibrin (test Group), In Immediate Implant Placement In Mandibular Molars.

Materials and Methods: 20 Patients And 20 Mandibular Molars Have Been Extracted And Replaced By Immediate Implant. Deproteinized Bovine Bone (Xenograft) Was Used As A Filling Material In Control Group While Platele-rich Fibrin Was Used As The Test Group. Cone Beam CT Was Obtained Preopetively, Immediately Post-operatively For Evaluation Of Implant Placement And 6 Months Postoperatively. Osstell Reading Were Taken At The Time Of Implant Placement And Implant Exposure (6 Months)

Results: Mean Bone Loss In The Xenograft Group Was 1.92� 1.0 While That Of The Platlet Rich Fibrin Group Was 1.3�0.78 And This Was Non-statistically Significant P=0.137. The Mean ISQ Value Of Guided Bone Regeneration Group Is 62.0�7.23, And 67.4�7.15 Platelet-rich Fibrin Group. This Was Statistically Nonsignificant P=0.110 Conclusion: Within The Limitation Of This Study, Immediate Implant Placement In Mandibular Molars With Guided Bone Regeneration Or Platelet Rich Fibrin Will Inevitably Result In Marginal Bone Loss. However, Implant Stability Has Shown Statistical Improvement In Both Groups.

Read More »

IMMEDIATELY LOADED SINGLE MEDIAN IMPLANT RETAINED MANDIBULAR OVER-DENTURES: EVALUATION OF CLINICAL OUTCOME

Mohamed Saleh, Sayed Abdel-Khalek And Nesreen El-Mekawy .,

ABSTRACT
BACKGROUND: Several Patients Notice The Value Of Completely Edentulous Mandibular Ridge Therapy Through Complete Overdenture Implants To Be On The Far Side Their Money Scope, Mandibular Overdentures Reatined By One Implant Are Reported To Be More Leisurely And Function Better Than Conventional Complete Dentures. The Goal Of The Current Study Were To Analyze The Clinical Outcomes In Comparison Between Two Types Of Attachments, The Locator Attachment Versus The Equator Attachment Used With Immediately Loaded Single Implant Retained Mandibular Overdenture Opposing Conventional Complete Denture. METHODS: Ten Completely Edentulous Patients Were Managed With A Single Implant Inserted Into The Midline Of The Mandible, Followed By Rehabilitation With Complete Dentures And Divided Into Two Equal Groups: Group I Patients Receive Locator Attachment, While Group II Receive Equator Attachment. Immediately After Implant Placement The Implant Stability Quotient (ISQ) Reading Of A Minimum Of 60 Was Measured Before Considering Connection Of The Attachment. Then The Denture Was Relieved In The Midline Providing Adequate Space For Female Housing Of The Attachment And Then The Denture Was Picked Up Directly In The Mouth. The Clinical Outcome Evaluated Two Weeks, Three Months And Six Months After Implant Insertion. RESULTS: The Peri-implant Soft Tissues Assessment Results Showed No Statistically Significant Difference Within Each Group And Between Two Groups At Different Evaluation Period, But The Result Of The Probe Depth In The Present Study Showed Statistically Significant Increase Within The Pair Groups, But There Is No Significant Variation Between The Pair Groups. CONCLUSION: Immediately Loaded Single Midline Implant Retained Mandibular Overdenture Treatment With Locator Attachment Could Be An Alternative And Cost Effective Treatment Option And Relatively Simply Treatment.

Read More »

THE EFFECT OF ZINC OXIDE NANO COATING ON FRICTIONAL RESISTANCE AND ANTIBACTERIAL BEHAVIOR OF NITI WIRES

Shaza M. Hammad, Noha A. El-Wassefy, Marwa Sameh And Ahmed Fathy,

ABSTRACT


Introduction: Friction In Orthodontics Should Be Controlled During All Stages Of Orthodontic Treatment. As High Friction Cause Prolonged Treatment, To Overcome Such Problem ,we Have To Increase Applied Force During Treatment That May Lead To Root Resorption And Loss Of Anchorage. Although Niti Wires Have Unique Properties Compared With Other Types Of Other Orthodontic Wires, They Have Disadvantages Of Surface Roughness And High Frictional Coefficient.
Objectives: To Investigate The Antibacterial Effect Of ZnO Nanocoating On Mechanical Properties Of NiTi Orthodontic Wires And Antibacterial Activity Of ZnO Coated Wires Against Microorganisms.

Read More »

ADAPTATION OF DENTURES FABRICATED USING THERMOPLASTIC VERSUS CONVENTIONAL ACRYLIC TRAYS: AN IN-VITRO STUDY

Omar Mohamed Ismail, Nouran Abdel Nabi And Iman AbdelWahab,

ABSTRACT
In The Present In-vitro Study, A Total Of 20 Denture Bases Were Fabricated On A Single Model Using Two Different Impression Techniques (ten With Each Technique). In The First Group, Impressions Were Recorded Using A Single Step Impression Technique Employing Preliminary Impressions Using Alginate With Stock Metal Trays Followed By Special Tray Fabrication And Secondary Impression Making Using Condensation Silicone Impression Material. In The Second Group, A Single Step Impression Technique Was Carried Out Using Thermoplastic Impression Trays Carrying Condensation Silicone Impression Material. The Final Denture Bases Were Then Compared In Terms Of Adaptation On The Model Cast Using A Stereo Microscope. The First Group Of Dentures Showed Better Adaptation Than The Second Group.

Read More »

THE EFFECT OF TWO DIFFERENT SURFACE TREATMENTS ON THE SURFACE TOPOGRAPHY AND WETTING ABILITY OF ZIRCONIA (AN IN VITRO STUDY)

Yasser M. Aly, Yousreya Shalaby Rania A Fahmy And Dwalat Mostafa,

ABSTRACT
Objective: Purpose Of This Study Was To Evaluate The Effect Of Airabrasion And Combined Air Abrasion & Ultraviolet Treatment On The Surface Topograghy And Wettability Of Zirconia Ceramic Materials.

Materials and Methods: Twenty One Zirconia Discs Were Fabricated From Copran Ceramic Zirconia, Then Were Grouped Into 3 Groups, Seven Specimens Each: (a) Air Abrasion (150um), (b) Air Abrasion & Ultra Violet Radiation, (c) Untreated Zirconia Discs. Surface Topography Was The Assessed By Scanning Electron Microscopy (SEM) And Atomic Force Microscopy (AFM). Wetting Ability Was Assessed By Contact Angle Measurement Test.

Results: Nano Topographic Surface Roughness Was Created In The Treated Groups With Significant Difference With The Untreated Group. Both Surface Treatments Enhanced The Wettability Of The Zirconia Discs

Conclusions: It Was Concluded That Both Air Abrasion And Combined Air Abrasion& Ultraviolet Treatments, Enhanced The Surface Topography Of Copran Zirconia Material By Producing Pronounced Nanoroughness .

Read More »

EVALUATION OF COMPUTER-ASSISTED CUSTOM MADE PLATES ON PATIENT SATISFACTION IN TERMS OF FUNCTION AND OCCLUSION IN OPEN REDUCTION AND INTERNAL FIXATION OF MANDIBULAR BODY FRACTURES (PILOT STUDY)

Doaa Abdel Fattah Abdel Hamid , Kadry Mohammed Nasr And Khaled Amr,

ABSTRACT
Objective: To Evaluate The Clinical And Radiographic Outcomes Of This Customized CAD/CAM Plate For Mandibular Body Fracture Reduction And Fixation.

Materials and Methods: Ten Patients With At Least A Unilateral Body Fracture Indicated For Open Reduction Internal Fixation .Preoperative Assessment And Preparation Was Done Through A Personal Data, Medical And Surgical History And Family History . After Detailed Clinical And Radiographic Evaluation Every Patient Underwent Routine Preoperative Laboratory Tests. Postoperatively Each Patient Was Followed Up At (two Days, Ten Days, Three Weeks, One And Half Month And Three Months From Day Of Surgery) For The Clinical Signs Relating To Stability Of The Osteosynthesis, Wound Healing, Infection, Occlusion.

Results: Clinical Results Showed That None Of The Cases Showed Clinical Manifestation Of Infection Form The Mandibular Body Segment Or From The Plate Postoperatively, Stable Fractured Segments Postoperatively, And The Corrected Occlusion Was Maintained In All Cases. Radiographic Results Showed Proper Reduction Of The Fractured Segment With Narrowing Of The Inter Fragmentary Gap. Conclusion: Custom Made Plates Fit On Every Person Specific Anatomy Giving Us Better Reduction With Excellent Results And Reduce The Time Of Bending And Fixing The Plate During Operation, Allow Patient To Return To Normal Function Rapidly Immediately After The Surgery (considering Good Nutrition And Verbal Communication), Allow The Prompt Recovery Of The Occlusion. Satisfy The Stress Condition And Produce High Stability, And The Use Of Computer Guided Technology Provided A Significant Improvement In The Field Of Osteosynthesis.

Read More »

EVALUATION OF COMPUTER-ASSISTED CUSTOM MADE PLATES ON PATIENT-ESTHETICS SATISFACTION IN GENIOPLASTY (PILOT STUDY)

Noha Essam Thabet , Kadry Nasr Geisa And Khaled Amr,

ABSTRACT

Objectives: Evaluation Of The Esthetics Satisfaction Of The Patient And Accuracy By Using Computer Assisted Custom Made Plates In Advancement Genioplasty. Patients And Methods: A Total Of Ten Patients Were Selected From The Out-patient Clinic At The Oral And Maxillofacial Surgery Department And Orthodontic Departments, Faculty Of Oral And Dental Medicine At Cairo University. Patients Were Indicated For Advancement Genioplasty Using Custom Made Plate And Its Bony Based Surgical Guide. The Surgery Was Performed On Adult Patient Age Range From 20 Till 30 Years Old Including 6 Females And 4 Males. Postoperatively Each Patient Was Followed Up 72 Hours, Ten Days, Three Weeks, One Half Month And Three Months Form Day Of Surgery And Then Monthly For 6 Months.

Results: All Patients With Advancement Genioplasty Recovered Totally From A Neurosensory Deficit. The Level Of Satisfaction Was Significantly High For All The Patients. The Results Were Judged To Be Excellent In 73.2% And Good In 26.8% Of The Cases. All Patients Were Satisfied With Their Appearance, Improved Motor Function, And Enhanced Quality Of Life. Conclusion: Computer Assisted Custom Made Plates With Its Bone Based Surgical Guide Designed On Mimics Software Aid In Producing Accurate Measurements Of Osteotomy Position And The Amount Of Chin Advancement. The Surgical Bony Guide And Custom Made Plate Help In Eliminating The Human Error And Save Time By Accurately Determining The Best Osteotomy Position According To The Previous Planed Measurements, As Well It Improves Patients Esthetics Satisfaction

Read More »

EFFECT OF THREE DIFFERENT REMINERALIZING AGENTS ON SHEAR BOND STRENGTH OF RESIN MODIFIED GLASS IONOMER TO DENTINE

Gomaa L.M, El Baz G.A , Abd Al Khalek W.M And Abo El Soud A. A .,

ABSTRACT


Aim: The Aim Of This Study Was To Evaluate And Compare The Effect Of Three Different Remineralizing Agents (GC Toothmousse, SHY-NM & Biorepair) On Shear Bond Strength Of Vitremer Resin Modified Glass Ionomer Cement To Dentine And To Determine The Mode Of Failure. Materials And Method: In This Study, 20 Sound Freshly Extracted Premolars Were Used. They Were Divided Into Four Groups, Five Each, Group I (control Group), Five Teeth (Mesial And Distal Surfaces) Were Restored With Resin Modified Glass Ionomer (Vitremer) Without Using Any Remineralizing Agents. In Group II: Teeth Were Treated With GC Tooth Mousse Then Restored With Vitremer. Group III: Teeth (ten Surfaces) Were Treated With SHY-NM Then Restored With Vitremer. Group IV: Teeth Were Treated BioRepair Plus Then Restored With Vitremer. Instron Universal Testing Machine Was Used To Assess The Shear Bond Strength. Light Microscopy (x20 Magnification) Was Used To Determine The Modes Of Failure.

Results: The Highest Shear Bond Strength Was In Group III After The Application Of Novamine Containing Paste ?Shy-NM?. While The Lowest Shear Bond Strength Was Found In The Group I (Control Group). For Groups II And IV, The Application Of Both GC Tooth Mousse And Biorepaire Increased The Shear Bond Strength Of Glass Ionomer After Their Application With No Significant Differences Between Them. The Most Frequent Failure Mode Was Adhesive (at Interface). Adhesive Failure Was Found In 27 Samples While The Remaining 13 Samples Were Mixed. Conclusion: The Shear Bond Strength Of Vitremer Resin Modified Glass Ionomer To Dentine Was Improved When Dentine Was Pre-treated With 5 % Novamin Containing Toothpaste, CPP-ACP Containing Paste, Toothpaste Made Of Hydroxyapatite Nanocrystals.

Read More »

NANOLEAKAGE OF ORMOCER-BASED VERSUS CONVENTIONAL ETCH AND RINSE ADHESIVES UNDER ORMOCER-BASED BULK-FILL RESIN COMPOSITE RESTORATION: IN VITRO STUDY

Hadier Mahmoud, Mona Ismail Riad And Mai Mamdouh .,

ABSTRACT


Aim: To Assess The Nanoleakage Of Ormocer-based Composite Resin Using Ormocer-based Etch And Rinse Adhesive Versus Conventional One. Environmental Scanning Electron Microscope (ESEM) And Image Analysis By Software Were Used To Evaluate The Tooth Restoration Interface.

Materials and Methods: A Total 66 Premolars Were Divided Into Two Main Groups According To Type Of Adhesive System Used Either Ormocer-based Adhesive System Or Conventional One, Each Group Was Further Divided Into Three Subgroups According To Storage Time Either 24 Hours, One Month Or Three Months.1mm Thick Beams Were Prepared And Immersed In The Tracer Solution. The Resin-dentin Interfaces Were Analyzed By An Environmental Scanning Electron Microscope (ESEM).

Results: A Non-significant Difference In The Nanoleakage Between Ormocer-based Adhesive And Conventional One For The 24 Hours And Three Months Storage Time. However, Significant Difference Between Ormocer-based Adhesive And Conventional One For One Month Storage Time Where Ormocer-based Adhesive Showed Less Nanoleakage. Conclusion: Tested Adhesives Showed Good Sealing Ability After Aging For Three Months; However, Ormocer Containing Adhesive Performed Better Than That None Containing Over Time With Less Linear Gaps And Silver Impregnation.

Read More »

ADVANCED SEARCH

© Copyright 2019, All Rights Reserved. | Powered by HPH